Data Line TVSS

TES 40
TES 42
TES 44
TES 46
TES 48

TES 40

Data Line Protection

Applications

Designed for marine instrumentation, communication, navigational radar, system monitors and controls.

Description

Fully self-contained. Enclosure is made of tough, lightweight cycolac ABS thermoplastic. UL 94V-0 for insulating, corrosion proof and flame retardant.
                     Lifetime Warranty!

Features

  • Eliminates dangerous voltage transients
  • Improves components and system reliability
  • Reduces lightning effects
  • Promotes personal safety
  • Clamps pico and nano seconds rise time transients
  • Wide operating temperature range
  • Low standby power consumption

Electrical Specifications

Voltage 12VDC-48VDC
Frequency DC Voltage
Operating Temperature -55C to +100C
Response Time < 5 N Sec
Technology Proprietary
This model comes in four modifications:
  • TES 40-12
  • TES 40-24
  • TES 40-32
  • TES 40-48
  • The second part of the part number represents the service voltage and the difference in the performance characteristics can be seen in the table below.

    Performance Specifications

    Service Voltage (VDC) Clamp Level Response Time Peak Current Capability 8/20 µsec Peak Power Capability
    12 16 5 n sec 1000 A 10,000 W
    24 33 5 n sec 1000 A 18,000 W
    32 41 5 n sec 1000 A 25,000 W
    48 68 5 n sec 1000 A 37,000 W
          (All line to line)  

    Installation

    TES 40 Installation Diagram